Loading… |
|
The Team at GEWINN Infra LLP (GIL) is young but with a huge experience into Marketing various Safety related products targeted towards Data Centres, Banking Industry, Malls, Hospitals etc. We Distribute / Market / Install & Undertake Servicing of Safety products all over India. Going forward we would like to launch innovative, environment friendly Safety related products in Indian Market focused towards Data Centres.
The AIR-Intelligence high-sensitivity smoke detection system (HSSD) provides superior early warning smoke detection that adapt to virtually any environment
ABC Powder Based Fire Extinguishers are made with supreme quality materials to robustly counter A B & C classes of fire. The extinguishers are also effective against electric fires. All our products, including these multipurpose fire extinguishers, have an intricate design which ensures that the products work without fail in any and every situation. these fire extinguishers are BIS and CE certified as well. The design of our ABC Powder Based Fire Extinguishers is made to suit the diverse requirements of our clients. That is why these extinguishers are available in various sizes and design types which safeguard our clients in all types of fire hazards.
ABC Powder Based Fire Extinguishers are made with supreme quality materials to robustly counter A B & C classes of fire. The extinguishers are also effective against electric fires. All our products, including these multipurpose fire extinguishers, have an intricate design which ensures that the products work without fail in any and every situation. these fire extinguishers are BIS and CE certified as well. The design of our ABC Powder Based Fire Extinguishers are made to suit the diverse requirements of our clients. That is why these extinguishers are available in various sizes and design types which safeguard our clients in all types of fire hazards.
ABC Powder Based Fire Extinguishers are made with supreme quality materials to robustly counter A B & C classes of fire. The extinguishers are also effective against electric fires. All our products, including these multipurpose fire extinguishers, have an intricate design which ensures that the products work without fail in any and every situation. these fire extinguishers are BIS and CE certified as well. The design of our ABC Powder Based Fire Extinguishers is made to suit the diverse requirements of our clients. That is why these extinguishers are available in various sizes and design types which safeguard our clients in all types of fire hazards.
ABC Powder Based Fire Extinguishers are made with supreme quality materials to robustly counter A B & C classes of fire. The extinguishers are also effective against electric fires. All our products, including these multipurpose fire extinguishers, have an intricate design which ensures that the products work without fail in any and every situation. these fire extinguishers are BIS and CE certified as well. The design of our ABC Powder Based Fire Extinguishers is made to suit the diverse requirements of our clients. That is why these extinguishers are available in various sizes and design types which safeguard our clients in all types of fire hazards.
ABC Powder Based Fire Extinguishers are made with supreme quality materials to robustly counter A B & C classes of fire. The extinguishers are also effective against electric fires. All our products, including these multipurpose fire extinguishers, have an intricate design which ensures that the products work without fail in any and every situation. these fire extinguishers are BIS and CE certified as well. The design of our ABC Powder Based Fire Extinguishers is made to suit the diverse requirements of our clients. That is why these extinguishers are available in various sizes and design types which safeguard our clients in all types of fire hazards.
Quick Overview Automatic operation Indoor use Easy to install 10 year lifetime No maintenance costs Effect: all types of fire A, B, C, F, in automatic mode of operation for extinguishing elektrical fires Friendly to humans and the environment (without halons) Can also be used as fire-extinguishing grenades Made in Slovenia Dimensions: 300mm x 90mm x ?60 mm Total weight: 1030 g Volume: 600 ml ampoule containing liquid extinguishing agent X-Fire in a sealed glass ampoule ampoule Details The purpose of X-Fire: X-Fire ampoules are designed to automatically extinguishing fires in small confined areas where potential sources of fire, usually electrical devices in continuous operation, but it is not guaranteed a permanent human presence. Are needed in all places where it is difficult access of people or if the opening accelerate the development of a fire in the room. Irreplaceable at all locations where it may first appear Exploding explosion, followed by a quick fire. The ampoule is recommended for the installation of the following features: automatic mode , which means the effective extinguishing of small fires and the protection of property and lives in households, businesses, boaters and others., no false alarms , it is activated only if there has been an increase in temperature, the ampoule can be used by throwing the origin of the fire, due to the simplicity of the human factor accounted for panic or confusion, the aestheticand reminiscent of the lamp, it does not cause further damage in the fire, because the rest of the liquid easy to wipe, isenvironmentally friendly extinguishing agent ( safe for humans and the environment); Life span: It has a long lifespan (10 years) no maintenance (care is necessary only that the glass is not damaged) Easy installation and removal in case of relocation. Safety: In Slovenia, the ampoule is tested at the Institute of Civil Engineering in Ljubljana (P 653/99-530-2: Firefighting oil in the kitchen, P 651/99-530-1: Firefighting flammable liquids). Based on the technical approval no. Relief GS 01 02 01 00, which was issued in 2001 by the Ministry of Defence, Administration for Civil Protection and Disaster Relief, the ampoule is issued for a declaration of conformity. Extras: Fire ampoules can be upgraded switch for activating the fire alarm at the fire headquarters, ampoule X-Fire may be protected by a safety net that prevents damage to glass, shoulder bag for storing vials if it carries with it the security guard at the longer rounds.
FEATURES & BENEFITS: Pin-Point Leak Location Precisely, tolerance +/-1m. (Indication by RED DOT) History/Event Log: 5,000 events. “Freezing” of selected zone(s) during maintenance/repair and no fault message generated. Readily connect to GSM modem / dialer for SMS fault notification. Modbus/TCP option available. Ability to Zoom-In onto each floor plan. Varies sizes of LCD monitor available upon request.
ELSA Advanced Systems is proud to present our latest innovation in Early Warning Liquid Leak Locating System, comprising of a Control Panel, Sensing Cable and accessories
Fire Suppression System or simply called as Automatic Fire Suppression System (or Gas Suppression System), is relatively a new technology in India. Fire Suppression System or simply called as Automatic Fire Suppression System (or Gas Suppression System), is relatively a new technology in India. Unlike conventional system that use water, in Gas Based Fire Suppression System; water is never used and yet the fire is extinguished. Here Gas is used to extinguish the fire. Hence it is a Gas Based system. The fire gets extinguished, within a minute of activation and everything is automatic. The Total Flooding Principle : The Fire Suppression System is used in an enclosed room or isolated location. The Local Application Principle : The Fire Suppression System is directly applied to the fire, immediately on the fire affected area. There are no physical barriers present, as in the case of the total flooding principle. The main advantage of Gas Suppression System, system is that it is very quick. The gas used in Gas Suppression System, does not have any smell or colour. It is also friendly to nature. Gas Suppression System also have very easy maintenance and occupy lesser space. It does not have any kind of flavour.
Quick Overview Automatic operation Indoor use Easy to install 10 year lifetime No maintenance costs Effect: all types of fire A, B, C, F, in automatic mode of operation for extinguishing elektrical fires Friendly to humans and the environment (without halons) Can also be used as fire-extinguishing grenades Made in Slovenia Dimensions: 300mm x 90mm x ?60 mm Total weight: 1030 g Volume: 600 ml ampoule containing liquid extinguishing agent X-Fire in a sealed glass ampoule ampoule Details The purpose of X-Fire: X-Fire ampoules are designed to automatically extinguishing fires in small confined areas where potential sources of fire, usually electrical devices in continuous operation, but it is not guaranteed a permanent human presence. Are needed in all places where it is difficult access of people or if the opening accelerate the development of a fire in the room. Irreplaceable at all locations where it may first appear Exploding explosion, followed by a quick fire. The ampoule is recommended for the installation of the following features: automatic mode , which means the effective extinguishing of small fires and the protection of property and lives in households, businesses, boaters and others., no false alarms , it is activated only if there has been an increase in temperature, the ampoule can be used by throwing the origin of the fire, due to the simplicity of the human factor accounted for panic or confusion, the aestheticand reminiscent of the lamp, it does not cause further damage in the fire, because the rest of the liquid easy to wipe, isenvironmentally friendly extinguishing agent ( safe for humans and the environment); Life span: It has a long lifespan (10 years) no maintenance (care is necessary only that the glass is not damaged) Easy installation and removal in case of relocation. Safety: In Slovenia, the ampoule is tested at the Institute of Civil Engineering in Ljubljana (P 653/99-530-2: Firefighting oil in the kitchen, P 651/99-530-1: Firefighting flammable liquids). Based on the technical approval no. Relief GS 01 02 01 00, which was issued in 2001 by the Ministry of Defence, Administration for Civil Protection and Disaster Relief, the ampoule is issued for a declaration of conformity. Extras: Fire ampoules can be upgraded switch for activating the fire alarm at the fire headquarters, ampoule X-Fire may be protected by a safety net that prevents damage to glass, shoulder bag for storing vials if it carries with it the security guard at the longer rounds.
Sometimes known as 'monitors', water cannons are fixed position fire extinguishing nozzles that can be used to directly target a fire at your facility. Although some of the engineering (such as pumps and water supply) may be similar to sprinkler and deluge systems, water cannons operate in quite a different manner. When combined with the with a Thermal Imaging system, water cannons provide a uniquely effective system to swiftly target fires, and even douse hotspot's before they develop into a blaze. ELSA 3L-TP-12. How Works Water cannons can be used as part of a Thermal Imaging system to automatically target and suppress an identified fire risk within seconds. The thermal imaging system is used as the detection system that continuously monitors the risk area for signs of a fire, or danger signs that a hotspot could be developing. On detection of a fire, the system then sends signals the water cannon that is mounted on a motorised chassis with a self-aligning system. This aligns the water jet directly at the risk area identified by the thermal imaging system and begins discharge at the fire. No other building protection automatic fire extinguishing system can operate with such speed and precision, dealing directly with the point of risk rather than blanket protecting a whole area. This targeted approach ensures that the risk is dealt with swiftly and efficiently and minimises clean-up costs.
FEATURES & BENEFITS: Application: Water and slightly-corrosive conductive liquids. Diameter size: 6mm average. Continuity wires: White & Red insulated with flame-retardant polymer. Sensing wires: 2 x Black wires, semi-conductive polymer. Carrier: Flame-retardant polymer material with greenish color in high visibility. Fire resistance: Non-flame propagating and self-extinguishing.
FEATURES & BENEFITS: Application: Highly-corrosive conductive liquids such as 100% Sulfuric Acid. Diameter size: 6mm average. Continuity wires: White & Red insulated with fire-resistant fluoropolymer. Sensing wires: 2 x Black wires, semi-conductive fire-resistant fluoropolymer. Carrier: Fire-resistant fluoropolymer material with yellowish color in high visibility. Fire resistance: UL910 (NFPA 262), highest Fire/Smoke standard.
Stratos-Micra 100 is designed to provide very high sensitivity smoke detection in a small package. ClassiFire Perceptive Artificial Intelligence ensures that the detector operates at optimum sensitivity for the protected environment, without the need for complex setup. This means the product will configure itself to provide high sensitivity in a computer room or reduced sensitivity in a smoky area. The detector is designed to fit into a Docking Station. All sampling pipes and cables are connected to the Docking Station as a first fix operation leaving the detector to be fitted during the final commissioning phase if required. This ensures that detectors are less likely to be damaged during the installation. Volt-free contacts ensure compatibility with any fire alarm system.
Stratos-Micra 25 is designed to provide very high sensitivity smoke detection in an ultra small package. ClassiFire Perceptive Artificial Intelligence ensures that the detector operates at optimum sensitivity for the protected environment, without the need for complex setup. This means the product will configure itself to provide high sensitivity in a computer room or reduced sensitivity in a smoky area. The detector is designed to fit into a Docking Station. All sampling pipes and cables are connected to the Docking Station as a first fix operation leaving the detector to be fitted during the final commissioning phase if required. This ensures that detectors are less likely to be damaged during the installation. Volt-free contacts ensure compatibility with any fire alarm system.
Stratos HSSD 2 is designed to provide very high sensitivity smoke detection for large areas. ClassiFire Perceptive Artificial Intelligence ensures that the detector operates at optimum sensitivity for the protected environment, without the need for complex setup. This means the detector will configure itself to provide high sensitivity in a computer room or reduced sensitivity in a smoky area. Volt-free contacts ensure compatibility with any fire alarm system. Each detector is provided with 3 monitored inputs. The inputs may be configured for a number of functions, see technical documentation for full details.
Used in HLLDS: LCD with backlight –4 lines, up to 35 characters Monitoring units –up to 40 units of 3L-DF/SM50 modules. Sensing Cable Length –up to 1,000m (25 m x 40pcs 3L-DF/SM50 Modules) Cable break location identification. Communication interface with BMS/EMS & High level RS485/Modbus interface protocol 4 x Relay (2-Trouble relay & 2-Leak relay) Alarm by Buzzer (90dB max.) and LED indicator
3L-HCS : Hydrocarbon Sensing Cable Sensing technology: Based on semiconductiveelastomeric material swelling property when in contact with non-conductive liquids of hydrocarbon (such as Diesel, Fuel, Crude Oil & etc). HCS cable shall consist of five wires enclosed within a PE braided sleeves (to protect the wires physically) throughout its whole length and terminated with a male and female connectors at each end respectively. No false alarm : It is non-sensitive to water, dirt, pressure, vibration, etc. High reliability: it remain reusable after simple cleaning solvents. Typical response time : Gasoline, Light Naphtha : 2 min 30 sec. Diesel, Oil, Jet Fuel : 5 min. Crude Oi l: 30 –60 min (depend on oil viscosity). Typical diameter : 10 mm Standard length : 2 m and 5 m (offer other customized length upon request) Accessories: 3L-T/L(HCS):Labeling Tag (Self adhesive) 3L-T/L(HCS):Labeling Tag (Self adhesive)
Aspiration Panel
GRENADE X-Fire BONPET With the “throw and extinguish” way we have added a new dimension of convenience and safety. Another innovative ampoule design made with Shatteract plastic resin makes it possible to fight fire by throwing the cartridge against fire from a safe distance Shatteract ampoule breaks only during impact but can withstand normal handling and storage Portable and light weight 600g Rapid Fire Extinguishment No. of ampoules depending upon the size and intensity of fires Fights class A, B and C fires Complete Maintenance free for 5 years Eco friendly and non- hazardous
Emergency Fire Fighting System (Fire Trolley) World’s first Battery OR Petrol Engine operated Emergency Fire Fighting System. Would replace 45 conventional extinguishers High pressure diaphragm pump with a flow rate of 25 liters per minute System capacity of 150 liters would provide 6 minutes of fire fighting equivalent to 45 conventional extinguishers Ideal for facilities without sprinkler or hydrant for Emergency Fire Response Can lance a distance of 40 feet as against 3 to 5 meters by conventional extinguisher Both jet type as well as mist type of spraying is available Trolley mounted provides mobility Equipment warranty of 5 years and Liquid performance warranty of 7 years
ELSA CONTROL PANEL 3L-AP – Locating Panel FEATURES & BENEFITS: Connect up to 192m (4-20mA) or 200m (RS485) of sensing cable and 300m of jumper cable. Precision of Leak Location: +/- 1m LCD display – 2 x 14 characters to display leaked location and cable break. Continue to detect leak if there is a cable break > Failed-Safe Loop Back Feature (class A wiring system). Sensitivity can be adjusted manually. 3x Dry contact relays > 2 x leaks and 1x cable-break signals out.
ELSA CONTROL PANEL 3L- DP – Locating Module FEATURES & BENEFITS: Connect up to 200m of sensing cable and 300m of jumper cable. Precision of Leak Location: +/- 1m Continue to detect leak if there is a cable break Failed-Safe Loop Back Feature (class A wiring system) RS485/Modbus (Open protocol) 1x Dry contact relay output for leak or cable-break. Sensitivity can be adjusted easily at site. Optional Features: Connect 3L-DP directly to 3L-SP or EMS/BMS with sensing cables to monitor large areas or multiple floors.
ELSA CONTROL PANEL 3L-NDP – Locating Panel FEATURES & BENEFITS: Maximum accumulated length of sensing cable : 10m Maximum accumulated length of jumper cable : 300m Failsafe Operation : Ability to operate in loop installation Ability to detect/locate liquid leakage during cable break. Time to detect Leak/Cablebreak : 3 seconds typical. Liquid leak detection data : Typically 20mm in length of liquid (such as tap water) in full contact with sensing cable, leak sensitivity is adjustable. Multi-leak detection and location capability. Remote supervision by RS-485 Modbus. ASIC-based digital location principle (patent pending) with inherent temperature stability, zero-drift and very low power consumption.
ELSA CONTROL PANEL 3L-NP – Non-Locating Module FEATURES & BENEFITS: S1+S2+…+Sn <=6 0m J1+ J2+…+ Jn <=1 00m Sensitivity can be adjusted manually. 1x Dry contact relay output for leak or cable-break Typical Application To monitor small room area (typically 20sqm) where leak can be located easily such as Pantry room, drip trays.
Enter mobile number